• Title of article

    Safety managements of the linear IFMIF/EVEDA prototype accelerator

  • Author/Authors

    Takahashi، نويسنده , , Hiroki and Maebara، نويسنده , , Sunao and Kojima، نويسنده , , Toshiyuki and Narita، نويسنده , , Takahiro and Tsutsumi، نويسنده , , Kazuyoshi and Sakaki، نويسنده , , Hironao and Suzuki، نويسنده , , Hiromitsu and Sugimoto، نويسنده , , Masayoshi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    5
  • From page
    2066
  • To page
    2070
  • Abstract
    On the Linear IFMIF/EVEDA Prototype Accelerator (LIPAc), the validation up to 9 MeV deuteron beam with 125 mA continuous wave is planned in Rokkasho, Aomori, Japan. Since the deuteron beam power exceeds 1 MW, safety issue related to γ-ray and neutron production is critical. To establish the safety management indispensable to reduce radiation exposure for personnel and activation of accelerator equipment, Personnel Protection System (PPS) of LIPAc control system, which works together with Radiation Monitoring System and Access Control System, was developed for LIPAc. The management of access to the accelerator vault by PPS and the beam duty management of PPS are presented in details.
  • Keywords
    Safety management , LIPAC , Personnel Protection System , Access control system , Radiation monitoring system , Operation Management
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2014
  • Journal title
    Fusion Engineering and Design
  • Record number