• Title of article

    Design of superheterodyne radiometer as ECE diagnostic for electron temperature profile measurement in SST-1

  • Author/Authors

    Pandya، نويسنده , , H.K.B and Atrey، نويسنده , , P.K and Govindarajan، نويسنده , , J and Mattoo، نويسنده , , S.K، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    4
  • From page
    469
  • To page
    472
  • Abstract
    This paper presents the design of an eight-channel W band radiometer as an electron cyclotron resonance (ECE) diagnostic to measure the electron temperature for phase I (Bt0 = 1.5 T) operation of SST-1. A double-sideband (DSB) mixer cum power divider method is used to cover the full range of ECE frequencies. The noise figure, sensitivity and expected output signal of the radiometer are estimated and a calibration technique is discussed. A time resolution of 5 μs and a spatial resolution of 0.6 cm for 2fce = 70 GHz are achieved by this radiometer.
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    1997
  • Journal title
    Fusion Engineering and Design
  • Record number

    2363472