Title of article :
Comparison of electron beam test facilities for testing of high heat flux components
Author/Authors :
Rِdig، نويسنده , , M and Akiba، نويسنده , , M and Chappuis، نويسنده , , P and Duwe، نويسنده , , R and Febvre، نويسنده , , M and Gervash، نويسنده , , A and Linke، نويسنده , , J and Litounovsky، نويسنده , , N and Suzuki، نويسنده , , S and Wiechers، نويسنده , , B and Youchison، نويسنده , , D.L، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
8
From page :
715
To page :
722
Abstract :
In the last few years, electron beam facilities for the testing of high heat flux components have been erected in Europe, Japan, Russia and in the USA. In principle all the facilities are comparable, but some machine parameters are quite different. These differences include electron beam operation (beam generation, beam diameter, sweeping mode), as well as the temperature measurement devices, calibration techniques and the definition of absorbed power densities. In order to assess the influence of these machine parameters and techniques on the results of high heat flux experiments, a round robin test has been performed in five facilities. In these tests, actively cooled CFC monoblock mock-ups were heated by electron beams using target power densities up to 15 MW/m2. Mock-up temperatures and their distribution, measured by different methods (IR camera, pyrometer, thermocouples), have been used as criteria for comparison. The evaluation of data from the different facilities shows good agreement for identical target loading conditions.
Keywords :
High heat flux components , Mock-up temperatures , Electron beam facilities
Journal title :
Fusion Engineering and Design
Serial Year :
2000
Journal title :
Fusion Engineering and Design
Record number :
2366361
Link To Document :
بازگشت