Title of article :
Shielding analysis for a heavy ion beam chamber with plasma channels for ion transport
Author/Authors :
Sawan، نويسنده , , M.E and Peterson، نويسنده , , R.R and Yu، نويسنده , , S، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
Neutronics analysis has been performed to assess the shielding requirements for the insulators and final focusing magnets in a modified HYLIFE-II target chamber that utilizes pre-formed plasma channels for heavy ion beam transport. Using 65-cm-thick Flibe jet assemblies provides adequate shielding for the electrical insulator units. Additional shielding is needed in front of the final focusing superconducting quadrupole magnets. A shield with a thickness varying between 45 and 90 cm needs to be provided in front of the quadrupole unit. The final laser mirrors located along the channel axis are in the direct line-of-sight of source neutrons. Neutronics calculations were performed to determine the constraints on the placement of these mirrors to be lifetime components.
Keywords :
Ion , Plasma channels , HYLIFE-II