Title of article :
Design criteria for Tore Supra high heat flux components
Author/Authors :
Missirlian، نويسنده , , M and Schlosser، نويسنده , , J and Lipa، نويسنده , , M and Mitteau، نويسنده , , R and Chappuis، نويسنده , , Ph and Portafaix، نويسنده , , C، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The need of high heat flux components (HHFCs) is significant in the fusion community. Such elements are required for divertor or limiter applications. The optimisation between performance and safety involved a large investment on design criteria. Based on the actual Tore Supra (TS) feedback and the recent work for Composant Interne Et Limiteur (CIEL) project with the newly developed component for Toroidal Pump Limiter (TPL), a review of the major thermal and mechanical design criteria is detailed in this paper.
Keywords :
High heat flux components , Tore Supra , Design criteria
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design