Title of article
Integration of direct-coupled diagnostics into ITER equatorial and upper ports
Author/Authors
Malaquias، نويسنده , , A and Costley، نويسنده , , A.E and Ebisawa، نويسنده , , K and Janeschitz، نويسنده , , G and Vayakis، نويسنده , , G and Walker، نويسنده , , C and Yamamoto، نويسنده , , S، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
5
From page
889
To page
893
Abstract
In a burning plasma machine like International Thermonuclear Experimental Reactor (ITER), diagnostic integration has to face among others, problems arising from the activation and dust contamination. The high flux of gamma rays and neutrons induces a deterioration of some diagnostic components imposing a relatively high rate of maintenance. Therefore, the design has to minimise the amount of radiation on diagnostic components and detection systems as well as making them as radiation hard as possible. Also, reliable and standardised remote handling (RH) procedures have to be developed for maintenance in an activated and dusty environment. The equatorial port #7 and upper port #10 presently integrates ten diagnostic systems. They require different types of vacuum connections: (i) extension of the primary vacuum, (ii) extension of the secondary vacuum and (iii) no vacuum extension. This paper describes the solutions for the implementation as well as the maintenance activities for the specific diagnostics installed on these ports.
Keywords
ITER , Diagnostics , X-Ray , reflectometry , Neutral particle analysis , nuclear fusion
Journal title
Fusion Engineering and Design
Serial Year
2001
Journal title
Fusion Engineering and Design
Record number
2366997
Link To Document