Title of article :
Development of a new discharge control system for JT-60 with a unix workstation and a VME-bus system
Author/Authors :
Totsuka، نويسنده , , T. and Akasaka، نويسنده , , H. and Sueoka، نويسنده , , M. and Takano، نويسنده , , S. and Yonekawa، نويسنده , , I.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
6
From page :
409
To page :
414
Abstract :
The old discharge control system (DCS) with HIDIC-80E mini-computer has been replaced by a control system with a unix workstation and a VME-bus system. Functionally, the workstation performs message communication with VME controller on the network, data processing using plant data and data acquisition. The commands and receiving the status data in real time. The new DCS is flexible for system extension and able to quickly respond to various requirements of software modifications. The data acquisition speed has been improved by almost a factor of two over the old one. Troubles and countermeasures experienced in the replacement work are also presented.
Keywords :
CAMAC , ETHERNET , Discharge control , Workstation , VME-bus , JT-60