• Title of article

    Development and testing of diagnostic windows for Tore Supra/CIEL and ITER

  • Author/Authors

    Lipa، نويسنده , , M and Portafaix، نويسنده , , C and Pluyette، نويسنده , , E and Walker، نويسنده , , C and Lochet، نويسنده , , N، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    6
  • From page
    801
  • To page
    806
  • Abstract
    For diagnostic applications in the Tore Supra/CIEL (TS) upgrade and ITER, sapphire–window assemblies have been developed. Thermo-mechanical analyses, which have been performed for different window–ferrule assemblies and loading cases, show the difficulty of stress evaluation due to uncertainties in the simulation of the bonding joint area. Consequently a prototype of the TS infrared endoscope head has been qualified following a baking and heat flux screening/cycling procedure in the infrared irradiation test facility (IRIFA). For ITER, five sapphire–window assemblies including, for comparison, six polycrystalline ceramic windows have been fabricated and tested, before neutron irradiation, according the ITER test specifications for normal duty events and accumulated normal life.
  • Keywords
    Window–ferrule assemblies , Polycrystalline ceramic windows , Sapphire
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2002
  • Journal title
    Fusion Engineering and Design
  • Record number