Abstract :
Temperature control performance of test pieces enclosed in IFMIF capsule by using single phase gas was estimated experimentally. The key issue of this study is to obtain the definite value of dimension of test facility and flow conditions of coolant and to clarify the temperature response of test piece to the beam-off scenario. Firstly, we have examined the cooling performance of the test cell originally proposed in IFMIF-KEP and from results of this calculation performed in three dimensional system by using brand-new turbulence model for flow and thermal fields, it is concluded that the drastical change of design of test cell is needed in order to obtain the unformity of temperatrure of test piece, to improve the responsibility of temperature measurement of test piece, and to relieve the coolant flow condition, especially for inlet pressure value. Thus, we have proposed new design of test cell and test piece arragement. A mock-up experimental facility was made based on our design and preliminary experiments for temperature control were performed. As a result, we have verified the cooling performance at the case that corresponds to two beam-off senario by using mock-up faciilty.
Keywords :
IFMIF , Design , Mock-up facility