Title of article :
Restoration performance of vertical ground heat exchanger with various intermittent ratios
Author/Authors :
Cao، نويسنده , , Xiaoling and Yuan، نويسنده , , Yanping and Sun، نويسنده , , Liangliang and Lei، نويسنده , , Bo and Yu، نويسنده , , Nanyang and Yang، نويسنده , , Xiaojiao، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2015
Pages :
7
From page :
115
To page :
121
Abstract :
Based on five intermittent operation modes with the intermittent ratios of 0.7, 1, 1.4, 2 and 3, the effect of intermittent operation on restoration performance of vertical ground heat exchanger in Ground Source Heat Pump was investigated in terms of heat exchange flux, temperature difference, soil temperature distribution and thermal radius. Meanwhile, a heat transfer model of the GHE has been developed by combining the analytical solution and numerical solution, whose calculation area has been divided into two parts by the boundary of the borehole wall. For the area in the borehole, the calculation method is steady analytical solution based on energy conservation, whereas for the soil area, the finite volume method is adopted, and the two parts are coupled by the temperature and heat flux of the borehole. The simulation results indicate that intermittence operation modes can improve the heat exchange performance of ground heat exchanger. Furthermore, when the intermittent ratio is 3, the restoration performance is the best due to the longest stopping time. With the operation proceeding, the enhancement of the heat flux arising from the intermittence becomes more obvious while the restoration ratio of average temperature of borehole decreases simultaneously.
Keywords :
Restoration performance , Ground source heat pump (GSHP) , Ground heat exchanger (GHE) , Intermittent operation
Journal title :
Geothermics
Serial Year :
2015
Journal title :
Geothermics
Record number :
2368428
Link To Document :
بازگشت