Title of article :
Present and perspective roles of soft X-ray tomography in tokamak plasma position measurements
Author/Authors :
Mlynar، نويسنده , , J. L. Duval، نويسنده , , B.P. and Horacek، نويسنده , , J. and Lister، نويسنده , , J.B.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
5
From page :
905
To page :
909
Abstract :
This paper shows the importance and feasibility of real-time tomography in fusion experiments for the example of soft X-ray (SXR) position measurements. The requirement of non-magnetic real-time diagnostics in low frequencies for ITER is discussed. This is illustrated by recent results of rapid tomographic inversion of SXR measurements on tokamak TCV. Comparison with the magnetic reconstruction data has not only shown the valuable resolution capabilities of both techniques, but also revealed a slight dependence of magnetic measurements on toroidal magnetic field and an unnoticed drift of plasma position observer. A feasibility study using current hardware capacities for programmable real-time tomographic system with plasma position feedback output was carried out. A compact solution is found to be tractable opening wide perspectives for development.
Keywords :
SXR , tokamak , TCV , MAGNETIC , Real-time , tomography , ITER
Journal title :
Fusion Engineering and Design
Serial Year :
2003
Journal title :
Fusion Engineering and Design
Record number :
2369418
Link To Document :
بازگشت