Title of article :
DC and transient current distribution analysis from self-field measurements on ITER PFIS conductor
Author/Authors :
Formisano، نويسنده , , A. S. Ilyin، نويسنده , , Yu. and Muzzi، نويسنده , , L. and Martone، نويسنده , , R. and Gislon، نويسنده , , P. and Nijhuis، نويسنده , , A. and Polak، نويسنده , , M. and Sborchia، نويسنده , , C. and Stepanov، نويسنده , , B.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
5
From page :
11
To page :
15
Abstract :
Current reconstruction in cable-in-conduit conductors (CICC) cables is a crucial issue to determine cables performance in working conditions, and must be performed using inverse problem approaches as direct measurement is not feasible. The current distribution has been studied for the ITER Poloidal Field Insert Sample (PFIS) conductor using annular arrays of Hall probes placed in three different locations along the sample during the test campaign at the SULTAN facility. The measurement apparatus is also described in the paper, together with the approach to current reconstruction.
Keywords :
ITER PFIS conductor , CICC cables , Current distribution analysis
Journal title :
Fusion Engineering and Design
Serial Year :
2005
Journal title :
Fusion Engineering and Design
Record number :
2369560
Link To Document :
بازگشت