Title of article :
Elimination of variable harmonics on motor generator circuit for experimental fusion facility
Author/Authors :
Yamada، نويسنده , , S. and Nakanishi، نويسنده , , Y. and Kojima، نويسنده , , H. and Hiue، نويسنده , , H. and Uede، نويسنده , , T. and Mito، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
5
From page :
93
To page :
97
Abstract :
A special active filter, which can eliminate the variable harmonic currents in continuity, was investigated. A variable-frequency band-pass filter was developed for the extraction of current component of fundamental frequency. Dynamic simulations for the active filter, motor generator with a flywheel (FW-MG) and power supplies of heating devices for the experimental fusion device of LHD have been carried. We found that the harmonic currents with the amplitudes of 20% have been reduced to less than 2% in the operational frequency range from 95 Hz to 55 Hz by using this active filter.
Keywords :
Harmonic current , Motor generator , LHD , active filter