• Title of article

    Elimination of variable harmonics on motor generator circuit for experimental fusion facility

  • Author/Authors

    Yamada، نويسنده , , S. and Nakanishi، نويسنده , , Y. and Kojima، نويسنده , , H. and Hiue، نويسنده , , H. and Uede، نويسنده , , T. and Mito، نويسنده , , T.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    5
  • From page
    93
  • To page
    97
  • Abstract
    A special active filter, which can eliminate the variable harmonic currents in continuity, was investigated. A variable-frequency band-pass filter was developed for the extraction of current component of fundamental frequency. Dynamic simulations for the active filter, motor generator with a flywheel (FW-MG) and power supplies of heating devices for the experimental fusion device of LHD have been carried. We found that the harmonic currents with the amplitudes of 20% have been reduced to less than 2% in the operational frequency range from 95 Hz to 55 Hz by using this active filter.
  • Keywords
    Harmonic current , Motor generator , LHD , active filter
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2005
  • Journal title
    Fusion Engineering and Design
  • Record number