• Title of article

    HETS performances in He cooled power plant divertor

  • Author/Authors

    Pizzuto، نويسنده , , Aldo and Karditsas، نويسنده , , Panos J. and Nardi، نويسنده , , Claudio and Papastergiou، نويسنده , , Stamos، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    4
  • From page
    481
  • To page
    484
  • Abstract
    In the frame of the activities aimed to evaluate the performances of a He cooled divertor in the future fusion power plant, the High Efficiency Thermal Shield (HETS) concept has been proposed. This concept relies on an abrupt change of momentum of the fluid in order to increase the turbulence in the gas, and therefore the heat transfer. quirements for the power plant divertor are, not only to sustain the required thermal flux (10 MW/m2), but He to have such properties as to be used directly in the energy production cycle and limit the required pumping power to no more than 10% of the divertor thermal power. Analytical studies developed by ENEA and UKAEA showed that the HETS concept can satisfy all the basic requirements. mental validations are required for the pressure drop estimates in HETS. Preliminary experiments have been performed using air at room temperature and showed values of pressure drop in line with the parameters used in the calculations. Studies aimed to optimize the shape of the channel, to further reduce the pressure drop are in progress.
  • Keywords
    High temperature brazing , Helium heat transfer , Tungsten and tungsten alloys , High heat flux components
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2005
  • Journal title
    Fusion Engineering and Design
  • Record number