• Title of article

    Measurement of beam power and profile for DNB on HT-7 tokamak

  • Author/Authors

    Liu، نويسنده , , Z.M. and Hu، نويسنده , , C.D. and Han، نويسنده , , X.P. and Li، نويسنده , , J. and Liu، نويسنده , , S. and Wan، نويسنده , , B.N.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    325
  • To page
    330
  • Abstract
    In normal experimental operation, a diagnostic neutral beam (DNB) can produce 6 A of extracted beam current in hydrogen at an energy of 49 keV with a pulse length of 100 ms. Hydrogen and deuterium beams can be produced as well. The diagnostic neutral beam has been added to the diagnostic set so that charge-exchange recombination spectroscopy (CXRS) can be used to acquire ion temperature and rotation. The beam power and beam profile distribution of the DNB injection can be obtained with a thermocouple probe measurement system on the HT-7 superconducting tokamak. The thermocouple probe measurement system with 13 thermocouples crossly distributed on the probe plate was used to measure the temperature rise of each coppery target, so the profile distribution of the ion/neutral beam was obtained by calculation. In this paper, the structure of the probe plate on the DNB for HT-7 tokamak and some measurement results are presented.
  • Keywords
    Diagnostic neutral beam , Target calorimeter system , Beams power , Beams profile distribution
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2007
  • Journal title
    Fusion Engineering and Design
  • Record number