Title of article
Optimization of optical filters for ITER edge Thomson scattering diagnostics
Author/Authors
Kajita، نويسنده , , Shin and Hatae، نويسنده , , Takaki and Naito، نويسنده , , Osamu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
7
From page
2214
To page
2220
Abstract
In the ITER edge Thomson scattering measurement system, polychromators with optical band-pass filters and avalanche photodiodes are planned to be used. In this paper, we optimized the transmission wavelength ranges of the optical filters by a numerical method. Since measurements in a high electron temperature range are required for the measurement system, the Thomson spectrum could overlap a strong line emission of D α when the electron temperature is rather high. It is shown that a filter whose transmission wavelength range is shorter than D α becomes important to decrease the measurement error in the high temperature range. Moreover, it is found that a filter whose transmission wavelength range is above 1064 nm (laser wavelength) is useful to improve the measurement accuracy, in particular, when the number of filters is more than six.
Keywords
Optical filter , Laser Thomson scattering , Polychromator , bremsstrahlung radiation
Journal title
Fusion Engineering and Design
Serial Year
2009
Journal title
Fusion Engineering and Design
Record number
2370039
Link To Document