Title of article
Operational performance of EAST cryogenic system and analysis of itʹs upgrading
Author/Authors
Qiu، نويسنده , , L.L. and Zhuang، نويسنده , , M. and Hu، نويسنده , , L.B. and Xu، نويسنده , , G.F. and Yuan، نويسنده , , C.Y.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
2821
To page
2826
Abstract
Since the first commissioning in February 2005, EAST cryogenic system was cooled down and warmed up for seven physics experimental campaigns. The operational performance of the cryogenic system, and heat loads released on different operational modes, together with cryogenic behaviors on magnets are presented in this paper. All of the thirteen pairs of current leads (CLs) in EAST tokamak have been upgraded to high temperature superconductor (HTS) current leads, so the liquefaction requirement for the refrigerator was greatly reduced and operational mode is quite different from the original optimization mode. In addition, when the physics experiments progress steadily, the requirements of the refrigeration are becoming higher. Furthermore, some components need to be replaced, because of low efficiencies or low stability. So the cryogenic system needs to be analyzed for upgrading. This paper presents the preliminary analysis.
Keywords
Cryogenic system , Helium refrigerator , Refrigeration process , Exergy analysis
Journal title
Fusion Engineering and Design
Serial Year
2011
Journal title
Fusion Engineering and Design
Record number
2370141
Link To Document