Abstract :
The JT-60 is planned to be modified to a full-superconducting tokamak referred to as the JT-60 Super Advanced (JT-60SA). The maximum temperature of the magnet during its quench might reach the temperature of higher than several hundreds Kelvin that will damage the superconducting magnet itself. The high precision quench detection system, therefore, is one of the key technologies in the superconducting magnet protection system. ck-up coil method, which is using voltage taps to detect the normal voltage, is used for the quench detection of the JT-60SA superconducting magnet system. The disk-shaped pick-up coils are inserted in the central solenoid (CS) module to compensate the inductive voltage. In the previous study, the quench detection system requires a large number of pick-up coils. The reliability of quench detection system would be higher by simplifying the detection system such as reducing the number of pick-up coils. Simplifying the quench detection system is also important to reduce the total cost of the protection system. Hence the design method is improved by increasing optimizing parameters. The improved design method can reduce the number of pick-up coils without reducing the sensitivity of detection; consequently the protection system can be designed with higher reliability and lower cost. The applicability of the disk-shaped pick-up coil for quench detection system is evaluated by the two dimensional analysis. In the previous study, however, the analysis model only took into account the CS, EF (equilibrium field) coils and plasma. Therefore, applicability of the disk-shaped pick-up coil for the quench detection system remains open question because the fast plasma events, such as disruption, mini collapse and ELM (edge localized mode), directly influences on the voltage of pick-up coil making the quench signal undetectable. Consequently, a new analysis model proposed in the present paper was designed to avoid this difficulty by introducing the passive coil series such as vacuum vessel and stabilizer. The influence of fast plasma events is absorbed by passive coil series like real system, and the evaluation of applicability can be examined in detail. The analysis results show that the disk-shaped pick-up coil is applicable whenever the standard operation, disruption, mini collapse and ELM.
Keywords :
JT-60SA , Pick-up coil , Disruption , Central solenoid , Quench detection
Journal title :
Fusion Engineering and Design
Serial Year :
2012
Journal title :
Fusion Engineering and Design
Record number :
2370168
Link To Document :
بازگشت