Title of article
The first DC performance test and analysis of CC conductor short sample at ASIPP conductor test facility
Author/Authors
Shi، نويسنده , , Yi and Wu، نويسنده , , Yu and Liu، نويسنده , , Huajun and Long، نويسنده , , Feng and Qian، نويسنده , , Li and Ren، نويسنده , , Zhibin and Li، نويسنده , , Shaolei and Liu، نويسنده , , Bo and Chen، نويسنده , , Jinglin، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
5
From page
179
To page
183
Abstract
The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270 mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (Tcs) in the 3.86 T external magnetic field (Bex), ≤12 kA could be measured including the critical current (Ic) run. There is no obvious impact of 1000 cycles on DC performance. Those measured Tcs results are in agreement with the expected results from strand scaling.
Keywords
CC conductor , DC performance test , Current sharing temperature
Journal title
Fusion Engineering and Design
Serial Year
2012
Journal title
Fusion Engineering and Design
Record number
2370188
Link To Document