• Title of article

    Piezo-valve controller for the gas inlet system of the fusion experiment Wendelstein 7-X

  • Author/Authors

    Schacht، نويسنده , , Jِrg and Sachtleben، نويسنده , , Jürgen and Jensen، نويسنده , , Hans and Stutz، نويسنده , , Ulli and Wiese، نويسنده , , Mathias، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    6
  • From page
    1961
  • To page
    1966
  • Abstract
    The gas inlet system of the fusion experiment Wendelstein 7-X (W7-X) comprises eleven gas inlets around the torus for controlled provision with working gases in the torus. This fast gas inlet system is designed for different operating modes of W7-X, from short discharges with only a few seconds durations to steady state plasma operation with operation time of 30 min. Piezo valves of type FGIS (FGIS: Fast Gas Injection System from General Atomics) are used as actuators for the W7-X gas inlet system. sign of an intelligent control unit for the FGIS Piezo valves are introduced and discussed. The integration of the valve controller units into the W7-X control component “W7-X gas inlet” and their planned application in an experiment run is described.
  • Keywords
    Piezo electrical valve , Valve controller unit , Gas inlet system
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2012
  • Journal title
    Fusion Engineering and Design
  • Record number