• Title of article

    Optimization of millimeter wave system in ITER Equatorial EC H&CD Launcher

  • Author/Authors

    Kajiwara، نويسنده , , K. and Takahashi، نويسنده , , K. and Oda، نويسنده , , Y. and Kobayashi، نويسنده , , N. and Sakamoto، نويسنده , , K.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    5
  • From page
    6
  • To page
    10
  • Abstract
    A high power (20 MW) and CW millimeter wave (mm-wave) injection is planned for Electron Cyclotron Heating and Current Drive (EC H&CD) in ITER. An optimization of the mm-wave system for the ITER EC H&CD Equatorial Launcher (EL) is performed. The optimization of the system is aimed to obtain the maximum transmission efficiency on the condition that 1.8 MW injection per waveguide, ∼20 cm in beam radius at the resonance layer and narrow opening of the Blanket Shielding Module (BSM). The transmission efficiency of 99.1% from the end of the waveguide inside the launcher to the output of the BSM is achieved. -wave propagation with high order modes is also calculated by using an experimentally obtained high power mm-wave beam pattern that includes 95%HE11, 0.6%LP11, 0.2%LP02 and 4.2% other higher order modes. The analysis predicts the 1–2% additional loss will be induced by the high order modes.
  • Keywords
    EC H& , CD Launcher , ITER , High power millimeter wave
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2014
  • Journal title
    Fusion Engineering and Design
  • Record number

    2370481