Title of article
Efficacy of polyacrylamide and protein flocculants in preventing anode depassivation induced Pb-contamination of copper electrowinning cathodes
Author/Authors
Tshimwanga، نويسنده , , Njinga and Maweja، نويسنده , , Kasonde and Tshula، نويسنده , , Kabongo، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
6
From page
240
To page
245
Abstract
The paper discusses the efficacy of Jaguar M50, Guarfloc 64, Superfloc N100, Separan NP10 and Floerger 912H flocculant additives in preventing contamination of Cu electrowinning cathodes by impurities like Pb. This was investigated in sulphate acid solutions at 60 °C. Results showed that mixing flocculants with Mersolat, a foaming-emulsifier (sodium alkane sulfonate) used to prevent corrosive emanations in electrowinning, minimises the volume of additive solutions. Washing the cathode surfaces using water at 60 °C is also seen to reduce Pb contents in electro-deposited copper metal.
gh all these flocculant additives can be used to limit copper cathode contamination by Pb, one also needs to consider the economic implications when selecting the appropriate flocculant for a given industrial application. This is because it was observed, in this study, that the best flocculant in limiting this contamination also adversely introduced higher cathode overpotentials, resulting in higher electrolysis specific energy consumption.
Keywords
Cu electrowinning , Passivating layer , Flocculant additives , Pb–Sb anodes , Pb-contamination