• Title of article

    Quantitative evaluation of optical lock-in and pulsed thermography for aluminum foam material

  • Author/Authors

    Duan، نويسنده , , Yuxia and Huebner، نويسنده , , Stefanie and Hassler، نويسنده , , Ulf and Osman، نويسنده , , Ahmad and Ibarra-Castanedo، نويسنده , , Clemente and Maldague، نويسنده , , Xavier P.V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    275
  • To page
    280
  • Abstract
    In this article, quantitative evaluation of optical thermographic techniques relative to the non-destructive inspection of aluminum foam material is studied. For this purpose, a set of aluminum foam specimens with flat-bottom holes (FBH) was inspected by both optical lock-in thermography (LT) and pulsed thermography (PT). Probability of detection (PoD) analysis, as a quantitative method to estimate the capability and reliability of a particular inspection technique, was studied and compared for both optical LT and PT inspection results.
  • Keywords
    Pulsed , thermography , lock-in , Aluminum Foam , POD
  • Journal title
    Infrared Physics & Technology
  • Serial Year
    2013
  • Journal title
    Infrared Physics & Technology
  • Record number

    2376351