Title of article
Single Beat Determination of Intraventricular Systolic Dyssynchrony in Patients with Atrial Fibrillation and Systolic Dysfunction.
Author/Authors
Sadeghpour، Anita نويسنده , , Hoghooghi، Alireza نويسنده Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran , , Alizadehsani، Zahra نويسنده Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran , , Rezaei، Mohsen نويسنده , , Aghapour، Sevil نويسنده Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran , , Haghjoo، Majid نويسنده Echocardiography Research Center, Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran. ,
Issue Information
فصلنامه با شماره پیاپی 0 سال 2013
Pages
5
From page
85
To page
89
Abstract
Atrial fibrillation (AF) is the most common clinically significant cardiac arrhythmia. However, diagnosis of intraventricular dyssynchrony in patients with AF is difficult due to beat-to-beat variation. Additionally, evaluation of mechanical dyssynchrony in the traditional method is based on average of 5 to 10 beats, which is exhausting and time consuming. Single-beat evaluation of a beat with equal subsequent cardiac cycles has been proposed as an accurate method in patients with AF. We proposed to evaluate intraventricular mechanical dyssynchrony by measuring time-to-peak systolic velocity between basolateral and basoseptal segments (septum to lateral wall delay) using Tissue Doppler Study (TDI) by two different methods. 31 patient (68 ± 10.3 years) with heart failure (EF < 35%) and AF rhythm, R-R cycle length more than 500 msec were evaluated. We found a target beat in which preceding R-R (R-R1) to pre-preceding R-R (R-R2) ratio was 1(RR1/RR2 = 1) then measured the intraventricular dyssynchrony in that cycle. Intraventricular dyssynchrony was also determined and averaged for 8 consecutive cardiac cycles. The values at RR1/RR2 = 1 were compared with the average of intraventricular dyssynchrony in eight cycles and the relationship between dyssynchrony were evaluated by paired T-test, linear Pearson correlation (r2), linear regression analysis. The average of dyssynchrony in eight cycles showed a positive correlation with dyssynchrony in target beat RR1/RR2 = 1. Average of dyssynchrony in target beat was 46.77 msec, and average of 8 cycle was = 47.701, (P value = 0.776, Pearson linear correlation 0.769). Measurement of intraventricular dyssynchromy in basoseptal and basolateral segments in AF and heart failure patients in a single beat with RR1/RR2 = 1 , were very similar to the average value of eight cardiac cycle.
Journal title
Research in Cardiovascular Medicine
Serial Year
2013
Journal title
Research in Cardiovascular Medicine
Record number
2380869
Link To Document