Title of article :
LES benchmark study of high cycle temperature fluctuations caused by thermal striping in a mixing tee
Author/Authors :
Hu، نويسنده , , Lin-Wen and Kazimi، نويسنده , , Mujid S. Kazimi.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Thermal striping is identified as one of the causes of thermal fatigue failure in nuclear power plants. Numerical studies of thermal striping require three-dimensional, unsteady turbulent modeling that resolves both large and small-scale turbulent motions. Benchmark studies were carried out using the LES turbulence model solved by the commercial CFD code FLUENT. Two types of mixing tee configurations were modeled to evaluate the performance of the CFD code. The simulation results presented in normalized average temperature and normalized fluctuating temperatures are in good agreement with measurements.
Keywords :
Turbulence , Large eddy simulation , Thermal striping
Journal title :
International Journal of Heat and Fluid Flow
Journal title :
International Journal of Heat and Fluid Flow