Title of article :
Water flow measurement in large bore pipes: An experimental comparison between two different types of insertion flowmeters
Author/Authors :
Cascetta، نويسنده , , Furio and Palombo، نويسنده , , Adolfo and Scalabrini، نويسنده , , Gianfranco، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
In this paper the metrological behavior of two different insertion flowmeters (magnetic and turbine types) in large water pipes is described. A master-slave calibration was carried out in order to estimate the overall uncertainty of the tested meters. The experimental results show that (i) the magnetic insertion tested flowmeter performs the claimed accuracy (±2%) within all the flow range (20:1); (ii) the insertion turbine tested meter, instead, reaches the claimed accuracy just in the upper zone of the flow range.
Keywords :
flow rate , Water flow measurement , Insertion technique , Magnetic and turbine flowmeters
Journal title :
ISA TRANSACTIONS
Journal title :
ISA TRANSACTIONS