Title of article
An opto-isolator based linearization technique of a typical thyristor driven pump
Author/Authors
Bera، نويسنده , , S.C. and Sarkar، نويسنده , , R. and Mandal، نويسنده , , N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
9
From page
220
To page
228
Abstract
A thyristor driven pump is operated by varying the DC input signal in the firing circuit of thyristor drive. This operation suffers from difficulties due to the nonlinear relation between thyristor output and DC input. In the present paper, an opto-isolator based linearization technique of a typical thyristor driven pump has been proposed. The design, fabrication and the necessary circuit diagram along with theoretical explanations of the resultant output has been described. The operation of the linearized thyristor driven pump has been studied experimentally and the experimental data before and after linearization are reported. The characteristic graphs are found to have very good linearity.
Keywords
Motor load current , Thyristor driven pump , Opto-isolator , PID controller , Inverse derivative control action , Linearization technique
Journal title
ISA TRANSACTIONS
Serial Year
2012
Journal title
ISA TRANSACTIONS
Record number
2383157
Link To Document