• Title of article

    In Vitro Comparison of Cone Beam Computed Tomography with Digital Periapical Radiography for Detection of Vertical Root Fracture in Posterior Teeth

  • Author/Authors

    Abdinian، Mehrdad نويسنده Dental Implants Research Center, Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. , , Razavian ، Hamid نويسنده Torabinejad Dental Research Center, Dept. of Endodontics, School of Dentistry, Isfahan University of Medical Scienc-es, Isfahan, Iran. , , Jenabi Dehkordi ، Nastaran نويسنده Student Dentistry, School of Dentistry, Isfahan University of Medical Sciences. Isfahan, Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی 51 سال 2016
  • Pages
    7
  • From page
    84
  • To page
    90
  • Abstract
    Statement of the Problem: The diagnosis of vertical root fracture (VRF) is a challenging task. Purpose: This in vitro study compared cone beam computed tomography (CBCT) imaging with digital periapical radi-ography (DPR) made by three different horizontal angels (20°mesial, 0° and 20° distal) for accurate diagnosis of VRF. Materials and Method: Among 120 posterior teeth included in this study, 60 were vertically fractured. Fractured and non-fractured teeth were randomly distributed into three groups defined as group 1 with no filling in the root canal, group 2 with gutta-percha in the canal, and group 3 with the intracanal post. All samples were placed in a dry mandible and imaged with CBCT and DPR techniques. Two blind observers investigated the images. Results: CBCT had higher sensitivity but lower specificity compared with DPR, except for the intracanal post group in which the sensitivity of DPR was higher; though the chi-square test showed the differences to be statistically insignifi-cant. The sensitivity, specificity, and accuracy of CBCT and DPR were reduced in the cases that gutta-percha or post were present in the canal. Inter-observer agreement was higher for CBCT. A set of three DPRs with different horizontal angels were significantly more sensitive for VRF recognition than a single orthogonal DPR. Conclusion: Based on our results, there was no significant difference between CBCT and a set of three DPRs with dif-ferent angulations for VRF detection in posterior teeth. Therefore, it is suggested to consider DPRs with three different horizontal angels (20°mesial, 0° and 20° distal) for radiographic evaluation before CBCT examination.
  • Journal title
    Journal of Dentistry :Shiraz University of Medical Sciences
  • Serial Year
    2016
  • Journal title
    Journal of Dentistry :Shiraz University of Medical Sciences
  • Record number

    2389129