Title of article :
Biodegradable nanocomposite coatings accelerate bone healing: In vivo evaluation
Author/Authors :
Mehdikhani-Nahrkhalaji، Mehdi نويسنده Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan , , Fathi، Mohammad Hossein نويسنده , , Mortazavi، Vajihesadat نويسنده , , Mousavi، Sayed Behrouz نويسنده Torabinejad Dental Research Center, Department of Endodontics , , Akhavan، Ali نويسنده Dental Materials Research Center, Department of Endodontics , , ESLAMI HAGHIGHAT، Abbas نويسنده , , Hashemi-Beni، Batool نويسنده 7Dental Materials Research Center, Department of Anatomical Sciences, School of Medicine, Isfahan University of Medical Sciences , , Razavi، Sayed Mohammad نويسنده Department of Oral and Maxillofacial Pathology, Isfahan University of Medical Sciences, Isfahan, Iran , , Mashhadiabbas، Fatemeh نويسنده Department of Pathology, Dental Research Center of Shahid Beheshti University of Medical Science, Tehran, Iran ,
Issue Information :
دوفصلنامه با شماره پیاپی 0 سال 2015
Pages :
11
From page :
89
To page :
99
Abstract :
Background: The aim of this study was to evaluate the interaction of bioactive and biodegradable poly (lactide-co-glycolide)/bioactive glass/hydroxyapatite (PBGHA) and poly (lactide-co-glycolide)/ bioactive glass (PBG) nanocomposite coatings with bone. Materials and Methods: Sol-gel derived 58S bioactive glass nanoparticles, 50/50 wt% poly (lactic acid)/poly (glycolic acid) and hydroxyapatite nanoparticles were used to prepare the coatings. The nanocomposite coatings were characterized by scanning electron microscopy, X-ray diffraction and atomic force microscopy. Mechanical stability of the prepared nanocomposite coatings was studied during intramedullary implantation of coated Kirschner wires (K-wires) into rabbit tibia. Titanium mini-screws coated with nanocomposite coatings and without coating were implanted intramedullary in rabbit tibia. Bone tissue interaction with the prepared nanocomposite coatings was evaluated 30 and 60 days after surgery. The non-parametric paired Friedman and Kruskal-Wallis tests were used to compare the samples. For all tests, the level of signifi cance was P < 0.05. Results: The results showed that nanocomposite coatings remained stable on the K-wires with a minimum of 96% of the original coating mass. Tissue around the coated implants showed no adverse reactions to the coatings. Woven and trabecular bone formation were observed around the coated samples with a minimum infl ammatory reaction. PBG nanocomposite coating induced more rapid bone healing than PBGHA nanocomposite coating and titanium without coating (P < 0.05). Conclusion: It was concluded that PBG nanocomposite coating provides an ideal surface for bone formation and it could be used as a candidate for coating dental and orthopedic implants.
Journal title :
DRJ Dental Research Journal
Serial Year :
2015
Journal title :
DRJ Dental Research Journal
Record number :
2390460
Link To Document :
بازگشت