• Title of article

    Surgical Management of Tibial Plateau Fractures With 3.5 mm Simple Plates

  • Author/Authors

    Bagherifard، Abolfazl نويسنده Bone and Joint Reconstruction Research Center, Shafa Orthopedic Hospital, Iran University of Medical Sciences, Tehran, IR Iran , , Jabalameli، Mahmoud نويسنده Department of Orthopedic Surgery, Shafa Yahyaiyan Hospital, Iran University of Medical Sciences, Tehran, Iran. Jabalameli, Mahmoud , Hadi، Hosseinali نويسنده University of Medical Science, Arak, IR Iran , , Rahbar، Mohammad نويسنده , , Minator Sajjadi، Mohammadreza نويسنده Taleghani Hospital Research Development Unit, Shahid Beheshti University of Medical Sciences, Tehran, IR Iran , , Jahansouz، Ali نويسنده Department of Orthopedic Surgery, Firouzgar Hospital, Iran University of Medical Sciences, Tehran, IR Iran , , Karimi Heris، Hossein نويسنده Bone and Joint Reconstruction Research Center, Shafa Orthopedic Hospital, Iran University of Medical Sciences, Tehran, IR Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی 0 سال 2016
  • Pages
    6
  • From page
    1
  • To page
    6
  • Abstract
    Tibial plateau fractures can be successfully fixed utilizing 3.5 mm locking plates. However, there are some disadvantages to using these plates. In the current prospective study, we investigated the outcome of treating different types of tibial plateau fractures with 3.5 mm simple plates which, to our knowledge, has not been evaluated in previous studies. Between 2011 and 2013, 32 patients aged 40 ± 0.2 years underwent open reduction and internal fixation for tibial plateau fractures with 3.5 mm simple plates. The patients were followed for 16.14 ± 2.1 months. At each patient’s final visit, the articular surface depression, medial proximal tibial angle, and slope angle were measured and compared with measurements taken early after the operation. The functional outcomes were measured with the WOMAC and Lysholm knee scores. The mean union time was 13 ± 1.2 weeks. The mean knee range of motion was 116.8° ± 3.3°. The mean WOMAC and Lysholm scores were 83.5 ± 1.8 and 76.8 ± 1.6, respectively. On the early postoperative and final X-rays, 87.5% and 84% of patients, respectively, had acceptable reduction. Medial proximal tibial and slope angles did not change significantly by the last visit. No patient was found to have complications related to the type of plate. In this case series study, the fixation of different types of tibial plateau fractures with 3.5 mm simple non-locking and non-precontoured plates was associated with acceptable clinical, functional, and radiographic outcomes. Based on the advantages and costs of these plates, the authors recommend using 3.5 mm simple plates for different types of tibial plateau fractures.
  • Journal title
    Trauma Monthly
  • Serial Year
    2016
  • Journal title
    Trauma Monthly
  • Record number

    2391210