Title of article :
Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth
Author/Authors :
Uzun، Ismail نويسنده Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey , , Gunduz، Kaan نويسنده Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey , , Celenk، Peruze نويسنده Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey , , Avsever، Hakan نويسنده Department of Dentomaxillofacial Radiology, Gulhane Military Medical Academy (GATA), Ankara, Turkey , , Orhan، Kaan نويسنده Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey , , Canitezer، Gozde نويسنده Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey , , Ozmen، Bilal نويسنده Department of Pedodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey , , Cicek، Ersan نويسنده Department of Endodontics, Faculty of Dentistry, Ondokuz Mayis University, Samsun, Turkey , , Egrioglu، Erol نويسنده Department of Statistics, Ondokuz Mayis University, Samsun, Turkey ,
Issue Information :
فصلنامه با شماره پیاپی 0 سال 2015
Pages :
7
From page :
1
To page :
7
Abstract :
The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. This study aimed to assess the use of different voxel resolutions of two different cone beam computerized tomography (CBCT) units in the detection VRFs in vitro. The study material comprised 74 extracted human mandibular single rooted premolar teeth without root fractures that had not undergone any root-canal treatment. Images were obtained by two different CBCT units. Four image sets were obtained as follows: 1) 3D Accuitomo 170, 4 × 4 cm field of view (FOV) (0.080 mm3); 2) 3D Accuitomo 170. 6 × 6 cm FOV (0.125 mm3); 3) NewTom 3G, 6˝ (0.16 mm3) and 4) NewTom 3G, 9˝ FOV (0.25 mm3). Kappa coefficients were calculated to assess both intra- and inter-observer agreements for each image set. No significant differences were found among observers or voxel sizes, with high average Z (Az) results being reported for all groups. Both intra- and inter-observer agreement values were relatively better for 3D Accuitomo 170 images than the images from NewTom 3G. The highest Az and kappa values were obtained with 3D Accuitomo 170, 4 × 4 cm FOV (0.080 mm3) images. No significant differences were found among observers or voxel sizes, with high Az results reported for all groups.
Journal title :
Iranian Journal of Radiology (IJR)
Serial Year :
2015
Journal title :
Iranian Journal of Radiology (IJR)
Record number :
2392015
Link To Document :
بازگشت