Title of article :
Correlation of Reconstructed Scaphoid Morphology with Clinical Outcomes
Author/Authors :
-، - نويسنده Department of Orthopedics, Urmia University of Medical Sciences, Urmia, Iran Afshar, Ahmadreza , -، - نويسنده Department of Radiology, Urmia University of Medical Sciences, Urmia, Iran Mohammadi, Afshin , -، - نويسنده Department of Orthopedics, Urmia University of Medical Sciences, Urmia, Iran Zohrabi, Kian , -، - نويسنده Department of Orthopedics, Urmia University of Medical Sciences, Urmia, Iran Navaeifar, Nasrin , -، - نويسنده Department of Orthopedics, Shafa Yahyaian Hospital, Iran University of Medical Sciences, Tehran, Iran Sami, Sam , -، - نويسنده Department of Orthopedics, Urmia University of Medical Sciences, Urmia, Iran Taleb, Hassan
Issue Information :
فصلنامه با شماره پیاپی 0 سال 2015
Pages :
6
From page :
244
To page :
249
Abstract :
-
Abstract :
  Background: Scaphoid malunion alters the carpal kinematics and impairs clinical outcome because of pain, weakness, restricted range of motion and predisposing the wrist joint to early osteoarthritis. The aim of this study was to evaluate the influence of the scaphoid morphological angles on clinical outcomes in patients with reconstructed scaphoid by non-vascularized bone graft. Methods: Seventeen male patients with the mean age of 31.7±3.7 years and mean non-union time of 31.5±14.7 months were enrolled in this retrospective study. Average follow up was 48.8±9.4 months. At the last follow-up, the patients were evaluated clinically for pain, wrist range of motion, grip strength, and wrist functional status. They were also evaluated radiologically by wrist radiographs and computerized tomography (CT). The overall clinical outcomes were evaluated by the Cooney wrist function score. The morphology of the reconstructed scaphoids was evaluated by the lateral intrascaphoid angle, antroposterior intrascaphoid angle, dorsal cortical angle, measuring the length (mm), and height-to-length ratio on CT scan. The radiological measurements were compared against the overall clinical outcomes. Results: There were 7 excellent, 7 good, 3 fair clinical results. The mean Cooney wrist function score was 83±4. The mean lateral intrascaphoid angle was 34.8±1.4 degrees, mean antroposterior intrascaphoid angle was 33.4±2.2 degrees, mean dorsal cortical angle was 158.3±4.8 degrees, mean scaphoid length was 22.1± 0.7 mm, and mean scaphoid height-to-length ratio was 0.74±0.04. There were no significant statistical correlations between the lateral intrascaphoid angles, antroposterior intrascaphoid angles, dorsal cortical angles, scaphoid lengths and scaphoid height-to-length ratios and Cooney wrist scores in the patients. Conclusion: In the current study, all the patients had some degree of scaphoid malunion; however, the radiological measurements of the reconstructed scaphoids did not correlate with the clinical outcomes.
Journal title :
The Archives of Bone and Joint Surgery
Serial Year :
2015
Journal title :
The Archives of Bone and Joint Surgery
Record number :
2392425
Link To Document :
بازگشت