Title of article :
Evaluation of the Corrosion of Five Different Bracket-Archwire Combination: An In-vitro Analysis Using Inductively Coupled Plasma Mass Spectrometry
Author/Authors :
Behroozi ، Zeinab نويسنده Dept. of Orthodontics, School of Dentistry, Yasuj University of Medical Science, Yasuj, Iran. , , Shahla ، Momeni Danaei نويسنده Orthodontic Research Center, Dept. of Orthodontics, School of Dentistry, Shiraz University of Medical Science, Shiraz, Iran. , , Sardarian، Ali Reza نويسنده Dept. of Chemistry, Collage of Sciences, Shiraz University, Iran. , , Moshkelghosha، Vahid نويسنده Orthodontic Research Center, Dept. of Orthodontics, School of Dentistry, Shiraz University of Medical Science, Shiraz, Iran. , , Sardarian ، Ahmad Reza نويسنده Orthodontic Research Center, Dept. of Orthodontics, School of Dentistry, Shiraz University of Medical Science, Shiraz, Iran. ,
Issue Information :
فصلنامه با شماره پیاپی Sup 3 سال 2016
Pages :
6
From page :
262
To page :
267
Abstract :
Statement of the Problem: Stainless steel brackets release metallic ions following the process of corrosion in the oral environment. These released ions have potential adverse effects on health, friction between wire and bracket, staining, strength of brackets. Choosing a bracket with favorable corrosive properties; therefore, should be a goal of every practitioner. Purpose: The goal of this study is to compare the amount of corrosion among five different brands of brackets using inductively coupled plasma (ICP) mass spectrometry. Materials and Method: Five different brands of brackets (Dentaurum, 3M, Ortho Organizer, Cobas and O.R.G) were chosen and ten brackets were selected from each brand. A piece of stainless steel wire was ligated to each bracket. The bracket-archwire complex was then immersed in artificial saliva. Subsequently, the samples were analyzed using an ICP device and the levels of iron, chromium, nickel, and manganese ions were measured. Results: The findings of this study demonstrated that iron was released the most from the tested brackets, followed by nickel. We also found that the Cobas bracket had the most ion release among the tested brackets (p < 0.05), while Ortho Organizer and ORG performed favorably. There was no significant difference between Dentaurum and 3M (p > 0.05). Conclusion: Based on the results, Ortho Organizer and ORG brackets are suggested in terms of resistance to corrosion.
Journal title :
Journal of Dentistry :Shiraz University of Medical Sciences
Serial Year :
2016
Journal title :
Journal of Dentistry :Shiraz University of Medical Sciences
Record number :
2393268
Link To Document :
بازگشت