Title of article :
THE EFFECTS OF HUMIDITY, COMPRESSOR OPERATION TIMEAND AMBIENT TEMPERATURE ON FROST FORMATION IN AN INDUSTRIAL FRIDGE
Author/Authors :
TAHAVVOR، A. R نويسنده , , HOSSEINI، S نويسنده ,
Issue Information :
دوفصلنامه با شماره پیاپی M1 سال 2015
Pages :
7
From page :
197
To page :
203
Abstract :
Fridges are used in various industries, and heat exchanger is one of the main components of these systems; therefore, efficiency analysis of these systems is very important. In many fridges, frost over the heat exchanger tubes or pipes affects the system operation and reduces heat transfer between the refrigerant and ambient, so defrosting systems are usually used to enhance heat transfer. Designing defrosting systems requires sufficient information about frost formation processes. Therefore, the objective of this study is experimental investigation of frost formation over a heat exchanger pipe in a pilot fridge. To do this, some steps are considered. For distinct cases, experiments are done to collect database for frost parameters under desired conditions. Then, based on experimental measurements some correlations are proposed for practical applications of frost growth and defrosting process over heat exchanger tubes.
Keywords :
Frost formation , Defrost , compressor operation time , fridge , Humidity
Journal title :
Iranian Journal of Science and Technology Transactions of Mechanical Engineering
Serial Year :
2015
Journal title :
Iranian Journal of Science and Technology Transactions of Mechanical Engineering
Record number :
2402206
Link To Document :
بازگشت