Title of article :
Do UV-blocking Soft Contact Lenses Meet ANSI Z80.20 Criteria for UV Transmittance?
Author/Authors :
Rahmani، Saeed نويسنده , , Mohammadi Nia، Mohadeseh نويسنده , , Akbarzadeh Baghban، Alireza نويسنده , , Nazari، Mohammadreza نويسنده , , Ghassemi-Broumand، Mohammad نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی سال 2015
Abstract :
Purpose:
To compare ultraviolet (UV) ray transmission in four UV-blocking soft contact lenses with Z80.20 standards set by the American National Standards Institute (ANSI).
Methods:
Four soft contact lenses including Acuvue Oasys (Johnson & Johnson, Ireland), Acuvue 2 (Johnson & Johnson, Ireland), Zeiss CONTACT Day 30 (Zeiss, Germany), and Sauflon 55 UV (Sauflon, UK) were evaluated for UV transmission. One-way ANOVA testing was performed to compare mean values of UVA and UVB transmission for the contact lenses.
Results:
Acuvue Oasys, Acuvue 2, Zeiss CONTACT Day 30 and Sauflon 55 UV showed UV-B transmittance values of 0.24%, 1.46%, 10.37%, and 2.52%, respectively. Corresponding values for UV-A transmittance were 20.81%, 33.49%, 44.03% and 42.53%, respectively. One-way ANOVA showed a statistically significant difference among the tested contact lenses in terms of UV-B (P < 0.001) and UV-A (P < 0.001) transmission.
Conclusion:
Acuvue Oasys met the ANSI criteria for UV transmission and may thus be a good choice for eye and vision care specialists and contact lens wearers seeking UV protection.
Keywords :
spectral transmittance , UV-blocking Contact Lens , ANSI Z80 , 20 Standard
Journal title :
Journal of Ophthalmic and Vision Research