• Title of article

    Comparison of sample preparation methods for determination of free carbon in boron carbide by X-ray powder diffraction

  • Author/Authors

    Bakhshi, Masoud Sooreh Company - Isfahan, Islamic Republic of Iran , Arab, Hamid Sooreh Company - Isfahan, Islamic Republic of Iran , Amini, Mohammad K Sooreh Company - Isfahan, Islamic Republic of Iran

  • Pages
    9
  • From page
    1673
  • To page
    1681
  • Abstract
    Several sample preparation methods were evaluated for determination of free carbon in boron carbide powders by quantitative X-ray diffraction method, including ultrasonication, wet ball milling and dry ball milling–wet mixing. Quantitation was based on measuring the integral peak area ratio of the diffraction lines of graphite (002) to boron carbide (012) in samples spiked with pure graphite. The dry milling–wet mixing method provided the best precision and accuracy in all the measurements as well as in determination of free carbon in a boron carbide reference material. There was a linear relationship between the integral peak area ratios and graphite added to boron carbide samples which were purified from their free carbon content. The method provided a low detection limit of 0.05 wt% free carbon.
  • Keywords
    Boron carbide , Free carbon , Quantitative XRD , Sample preparation , Graphite
  • Journal title
    Astroparticle Physics
  • Serial Year
    2016
  • Record number

    2406720