Title of article :
Raschig Rings Versus PVC as a Packed Tower Media in Scrubbing Ammonia from Air
Author/Authors :
Jafari, Mohammad Javad Department of Occupational Health - School of Public Health - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Omidi, Leila Department of Occupational Health - School of Public Health - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Rezazadeh Azari, Mansour Department of Occupational Health - School of Public Health - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Massoudi Nejad, Mohammad Reza Department of Occupational Health - School of Public Health - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Namdari, Mahshid Department of Biostatic - School of Paramedical Science - Shahid Beheshti University of Medical Sciences, Tehran, Iran
Pages :
7
From page :
270
To page :
276
Abstract :
The selection of the packing media is concerned when ammonia is going to be scrubbed through a packed tower. In this study, a packed tower with two types of packing including raschig rings and PVC were used to remove the ammonia gas from air stream. Three gas flow rates as well as three ammonia concentrations and three pH of scrubbing liquid were applied. The level of ammonia at the inlet and out let of the packed tower was measured through a direct reading device. The removal efficiency of column significantly increased in both modes, packed with raschig rings and PVC (p<0.001) as the inlet concentration of ammonia gas wasincreased. With decreasing pH of scrubbing liquid from 7 to 5, the removal efficiency of the tower packedwith raschig rings significantly increased (p< 0.01). The head loss across the bed was significantly increased(p< 0.001) as air flow rate increased from 5 to 10 and 10 to 15 l/s. The head loss across the bed was also higherwhen column was packed with racshig rings rather than packed with PVC. The lower ammonia removalefficiency of PVC rings could be ignored considering their other advantages such as light weight, low headlosses, low initial and operating costs.
Farsi abstract :
انتخاب بستر پركننده براي حذف گاز آمونياك در ستون پرشده اهميت زيادي دارد. در اين مطالعه يك برج پرشده با دو نوع ماده پركننده شامل حلقه هاي راشيگ سراميكي و PVC براي حذف گاز آمونياك از جريان هوا مورد استفاده قرار گرفت. هوا در سه گذر حجمي، گاز آمونياك در سه دامنه ي تراكم، و مايع شستشو در سه pH بكار گرفته شد. غلظت گاز آمونياك در ورودي و خروجي برج پرشده توسط تجهيزات قرائت مستقيم اندازه گيري گرديد. راندمان حذف ستون پرشده با افزايش غلظت آمونياك ورودي در هر دو نوع بستر پرشده بوسيله ي حلقه هاي راشيگ سراميكي و PVC بطور معني دار افزايش يافت (P> 001.0 )با كاهش pH مايع شستشو از 7 به 5 راندمان حذف ستون پرشده با حلقه هاي راشيگ سراميكي بطور معني دار افزايش يافت (01. P< 0 )با افزايش گذر حجمي هوا از 5 به 10 و از 10 به 15 ليتر بر ثانيه، افزايش معني داري (P< 001.0 )در افت فشار ستون در هر دو نوع بستر پركننده مشاهده گرديد اما اين افت فشار افزايش يافته در ستون پر شده بوسيله ي حلقه هاي راشيگ سراميكي بيشتر بود. با وجود راندمان حذف كمتر ستون پر شده توسط حلقه هاي PVC نسبت به حلقه هاي راشيگ سراميكي، ساير مزاياي اين نوع پركننده از قبيل وزن پايينتر، افت فشار كمتر و هزينه ي اوليه و نگهداري پايين تر سبب مي شود بيشتر مورد پذيرش و استفاده قرار گيرد
Keywords :
Racshig rings , PVC , Packed tower , Ammonia removal , Efficiency , pH