Author/Authors :
Fayazi, Maryam Department of Physical Therapy - Rehabilitation faculty - Tehran University of Medical Sciences, Tehran, Iran , Noorizadeh Dehkordi, Shohreh Department of Physical Therapy - Rehabilitation faculty - Tehran University of Medical Sciences, Tehran, Iran , Dadgoo, Mehdi Department of Physical Therapy - Rehabilitation faculty - Tehran University of Medical Sciences, Tehran, Iran , Salehi, Masoud Department of Physical Therapy - Rehabilitation faculty - Tehran University of Medical Sciences, Tehran, Iran
Abstract :
Background: The Motricity Index was used to measure strength in upper and lower extremities after stroke.
The weighted score based on the ordinal 6 point scale of Medical Research Council was used to measure maximal
isometric muscle strength. There is dearth of articles dealing with the reliability of this method. Therefore,
the aim of this study was to determine the test retest reliability of Motricity Index strength assessments for paretic
lower limb in 20 chronic stroke patients with one week interval.
Methods: In a cross sectional study, intrarater reliability of lower extremity Motricity Index strength assessments
with one week interval were measured.
Result: The SPSS 18 was used for analysis of data. Two-way random-consistency model of ICC was used for
assessment of test-retest reliability. The ICC values showed high reliability of strength measurement of
Motricity Index (ICC=0.93).
Conclusion: The Motricity Index can be a reliable instrument for measuring the strength of involved lower extremity
when assessment is done by one rater following chronic stroke.
Keywords :
Chronic stroke , Hemiparesis , Motricity Index , Reliability