Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture
Author/Authors :
Rafighdust, Abbasali Imam Reza Hospital - Mashhad University of Medical Sciences , Eshraghi, Ali Imam Reza Hospital - Mashhad University of Medical Sciences
Pages :
3
From page :
205
To page :
207
Abstract :
The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good. J Teh Univ Heart Ctr 2015;10(4):205-207 This paper should be cited as: Rafighdust AA, Eshraghi A. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture. J Teh Univ Heart Ctr 2015;10(4):205-207.
Keywords :
Myocardial infarction , Treatment failure , Drug-eluting stents , Stents