• Title of article

    An evaluation of the Flexural Properties of Meliodent and Acropars Heat Polymerized Acrylic Resins

  • Author/Authors

    Golbidi, F Department of Prosthodontics and Torabinejad Dental Research Center - School of Dentistry - Isfahan University , Jalali, O

  • Pages
    4
  • From page
    68
  • To page
    71
  • Abstract
    Objective: The aim of this study was to measure and compare the transverse strength and deflection of two acrylic resins. Method and Materials: A total of 30 samples, with dimensions of 2.5×10×65mm, were prepared with Acropars and Meliodent acrylic resins according to ADA specification No. 12. The specimens were divided into two groups of 15 samples each. A three-point bending test was carried out using a universal testing machine. Differences between the means of the two groups were analyzed with Student's t-test. Results: The mean (SD) transverse strength was 81.55 (1.54) Mpa in the Meliodent and 73.58 (0.6) Mpa in the Acropars samples, which showed a significant difference (P<0.001). The mean (SD) transverse deflection was 3.86 (0.09) mm and 4.96 (0.06) mm in the Meliodent and Acropars samples, respectively. A significant difference was found between the two groups (P<0.001). Conclusion: In the present investigation, the transverse strength of the Acropars specimens was smaller than that of the Meliodent samples and ADA specifications. However, the mean transverse deflection was larger in the Acropars group as compared to the Meliodent group.
  • Keywords
    Heat polymerized acrylic resin , Transverse deflection
  • Journal title
    Astroparticle Physics
  • Serial Year
    2007
  • Record number

    2421975