• Title of article

    Comparison of Short and Standard Implants in the Posterior Mandible: A 3D Analysis Using Finite Element Method

  • Author/Authors

    Geramy, Allahyar Tehran University of Medical Sciences, Tehran , Rokn, Amirreza Tehran University of Medical Sciences, Tehran , Keshtkar, Abbasali Department of Health Sciences Education Development - School of Public Health, Tehran University of Medical Sciences, Tehran , Monzavi, Abbas Tehran University of Medical Sciences, Tehran , Mahmood Hashemi, Hamid Tehran University of Medical Sciences, Tehran , Bitaraf, Tahereh Tehran University of Medical Sciences, Tehran

  • Pages
    7
  • From page
    130
  • To page
    136
  • Abstract
    Objectives: This study aimed to analyze functional stresses around short and long implant- supported prostheses with different crown heights. Materials and Methods: Four three-dimensional (3D) models were designed with SolidWorks 2015. In models 1 (control) and 2, three dental implants (second premolar 4.1x8 mm, molars: 4.8x8 mm) were placed. In models 3 and 4, three dental implants (second premolar 4.1x4 mm, molars: 4.8x4) were placed. Residual bone height was 10 mm in groups 1 and 2 (grafted bone) models and 6 mm in groups 3 and 4. The crown heights were modeled at 11.5 mm for groups 1 to 3, and 15 mm for group 4. The applied oblique force was 220 N to simulate chewing movements. The maximum von Mises and principal stresses on the implants and the supporting tissues were compared using the 3D finite element method. Results: In all models, the highest stress value was seen within the most coronal part of bone (crestal bone), which was cortical or grafted bone. The highest stress values in the bone supporting the implant neck were seen in the premolar region of each model, especially in model 4 (291.16 MPa). The lowest stress values were demonstrated in the molar region of model 3 (48.066 MPa). The model 2 implants showed the highestvon Mises stress concentrated at their neck (424.44 MPa). Conclusions: In atrophicposterior mandible with increased crown height space, short implants with wider diameter seem to be a more feasible approach compared to grafting methods.
  • Keywords
    Dental Implants , Dental Prosthesis Design , Dental Stress Analysis , Finite Element Analysis , Alveolar Ridge Augmentation
  • Journal title
    Astroparticle Physics
  • Serial Year
    2018
  • Record number

    2426431