Title of article :
The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Author/Authors :
Farshidfar, Z. MSc of Medical Imaging Technology (MRI) - Radiology Department of Paramedical School - Shiraz University of Medical Sciences, Shiraz, Iran , Faeghi, F. Radiology Technology Department - School of Allied Medical Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Haghighatkhah, H. R. Department of Radiology - Shohada Tajrish Hospital - Shahid Beheshti University of medical sciences, Tehran, Iran , Abdolmohammadi, J. MSc. of Medical Imaging Technology (MRI) - Department of Radiology - Faculty of Paramedical Sciences, Kurdistan University of Medical Sciences, Sanandaj, Iran
Abstract :
Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is evaluating the efficiency of different MRI sequences in order to better detection of
MS plaques.
Materials and methods: In this cross-sectional study which was performed at Shohada-E Tajrish in Tehran - Iran hospital between October, 2011 to April, 2012,
included 20 patients who suspected to MS disease were selected by the method of random sampling and underwent routine brain Pulse sequences (Axial T2w, Axial T1w, Coronal T2w, Sagittal T1w, Axial FLAIR) by Siemens, Avanto, 1.5 Tesla system. If any lesion which is suspected to the MS disease was observed, additional
sequences such as: Sagittal FLAIR Fat Sat, Sagittal PDw-fat Sat, Sagittal PDw-water sat was also performed.
Results: This study was performed in about 52 lesions and the results in more than 19 lesions showed that, for the Subcortical and Infratentorial areas, PDWw
sequence with fat suppression is the best choice, and in nearly 33 plaques located in Periventricular area, FLAIR Fat Sat was the most effective sequence than both PDw
fat and water suppression pulse sequences.
Conclusion: Although large plaques may visible in all images, but important problem in patients with suspected MS is screening the tiny MS plaques. This study showed that for revealing the MS plaques located in the Subcortical and Infratentorial areas, PDw-fat sat is the most effective sequence, and for MS plaques in the
periventricular area, FLAIR fat Sat is the best choice.
Keywords :
Multiple Sclerosis , MRI , PDW fat suppression , PDW water suppression , FLAIR
Journal title :
Astroparticle Physics