Title of article
The performance of hemoglobin A1c against fasting plasma glucose and oral glucose tolerance test in detecting prediabetes and diabetes
Author/Authors
Karakaya, Jale Departments of Biostatistics and Endocrinology and Metabolism - Faculty of Medicine - Hacettepe University - Ankara, Turkey , Akin, Safak Departments of Biostatistics and Endocrinology and Metabolism - Faculty of Medicine - Hacettepe University - Ankara, Turkey , Karagaoglu, Ergun Departments of Biostatistics and Endocrinology and Metabolism - Faculty of Medicine - Hacettepe University - Ankara, Turkey , Gurlek, Alper Departments of Biostatistics and Endocrinology and Metabolism - Faculty of Medicine - Hacettepe University - Ankara, Turkey
Pages
7
From page
1051
To page
1057
Abstract
Background: In recent years, hemoglobin A1c (HbA1c) is accepted among the algorithms used for making diagnosis for diabetes
and prediabetes since it does not require subjects to be prepared for giving a blood sample. The aim of this study is to assess the
performance of HbA1c against fasting plasma glucose (FPG) and oral glucose tolerance test (OGTT) in detecting prediabetes and
diabetes. Materials and Methods: A total of 315 subjects were included in this study. The success of HbA1c in distinguishing
the three diagnostic classes was examined by three-way receiver operating characteristic (ROC) analysis. The best cut-off
points for HbA1c were found for discriminating the three disease status. Results: The performance of HbA1c, measured by the
volume under the ROC surface (VUS), is found to be statistically significant (VUS = 0.535, P < 0.001). The best cut-off points for
discriminating between normal and prediabetes groups and between prediabetes and diabetes groups are c1 = 5.2% and c2 = 6.4%
respectively. Conclusion: The performance of HbA1c in distinguishing between the prediabetes and diabetes groups was higher
than its ability in distinguishing between healthy and prediabetes groups. This study provides enough information to understand
what proportion of diabetes patients were skipped with the HbA1c especially when the test result is healthy or prediabetes. If a
subject was diagnosed as healthy or prediabetes by HbA1c, it would be beneficial to verify the status of that subject by the gold
standard test (OGTT and FPG).
Keywords
volume under receiver operating characteristic surface , receiver operating characteristic surface , three-way receiver operating characteristic , hemoglobin A1c , Diabetes mellitus
Journal title
Astroparticle Physics
Serial Year
2014
Record number
2430252
Link To Document