• Title of article

    Assessment of endothelium: Dependent vasodilation with a non-invasive method in patients with preeclampsia compared to normotensive pregnant women

  • Author/Authors

    Allameh, Zahra Isfahan University of Medical Sciences, Isfahan , Ghasemi Tehrani, Hatav Isfahan University of Medical Sciences, Isfahan , Hashemi, Mohammad Isfahan University of Medical Sciences, Isfahan , Basirat Nia, Reza Isfahan University of Medical Sciences, Isfahan , Hoseini, Forough Isfahan University of Medical Sciences, Isfahan

  • Pages
    3
  • From page
    175
  • To page
    177
  • Abstract
    Background: To assess the endothelial function via noninvasive method, in pregnant women with preeclampsia compared to to normotensive pregnant women. Materials and Methods: Brachial artery diameter was measured via ultrasound, in 28 women with preeclampcia in case group and normotensive pregnant women in control group, at rest, after inflation of sphygmomanometer cuff up to 250-300 mmHg, immediately after deflation of the cuff, 60-90 minutes later and 5 min after administration of sublingual trinitroglycerin (TNG). Results of these measurements as well as demographic characteristics of participants in both groups were recorded in special forms. Data were analyzed via Statistical Package for Social Sciences (SPSS) version 16, using t-test and repeated measures analysis of variance (ANOVA). P-value < 0.05 was considered statistically significant. The results were presented as mean ± standard deviation (SD). Results: The mean of brachial artery diameter at rest in the case and control groups was 4.49 ± 0.39 and 4.08 ± 0.38 mm, respectively (P = 0.1). Also the results showed that the brachial artery diameter, immediately after deflation of the cuff, was 4.84 ± 0.4 and 4.37 ± 0.30 mm in the case and control groups (P < 0.001), respectively. The mean brachial artery diameter, 60-90 s after deflation of the cuff, was 4.82 ± 0.41 and 4.42 ± 0.38 mm in the case and control groups (P < 0.00), respectively. The brachial artery diameter, 5 min after sublingual NO administration, was 4.95 ± 0.6 and 4.40 ± 0.45 mm in case and control groups (P < 0.001), respectively. Applying of repeated measures ANOVA showed that the mean difference between case and control groups was statistically significant (P < 0.001). Conclusion: Current study concluded that there is no difference in endothelium-dependent vasodilation between women with preeclampsia and pregnant women with normal blood pressure.
  • Keywords
    Brachial artery diameter , endothelium-dependent vasodilation , Endothelium-dependent vasodilation-Preeclampsia- Nitric oxide (NO) , normotensive , NO , preeclampsia
  • Journal title
    Astroparticle Physics
  • Serial Year
    2014
  • Record number

    2432520