Title of article
Exploring the Efficiency of Dampers for Repair and Strengthening of Existing Buildings
Author/Authors
Barati, F. Shoushtar Branch, Islamic Azad University, Shoushtar, Iran , Esfandiari, A. Amirkabir University of Technology, Tehran, Iran
Pages
7
From page
67
To page
73
Abstract
In this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. Seismic performance of6-
story, 9-story and 12-story steel buildings with damper and without damper were studied. The finite element modeling
technique (SAP2000 Software) is used for analysis. Time History analyzing was done to achieve this purpose. For nonlinear
dynamic analysis, the responses of the structures to three earthquake records (Tabas, Naghan, and artificial waveform) were
obtained. A series of analyses were made to determine the optimum slip load of the friction dampers to achieve minimum
response. Also, in order to evaluate the performance of the friction dampers in asymmetric structures, an asymmetric
structure was utilized. The obtained results show significant improvement of seismic behavior and efficiency of the friction
damper for seismic retrofitting to these buildings.
Keywords
Friction damper , Slip load , Nonlinear dynamic analysis , Seismic retrofitting , existing building
Journal title
Astroparticle Physics
Serial Year
2012
Record number
2437974
Link To Document