Title of article
Objective and subjective assessing efficacy of a lubricating drop in eyes wearing silicone hydrogel contact lenses
Author/Authors
Asharlous, Amir Optometry Department - School of Paramedical Sciences - Mashhad University of Medical Sciences , Mirzajani, Ali Optometry Department - Iran University of Medical Sciences, Tehran , Jafarzadehpur, Ebrahim Optometry Department - Iran University of Medical Sciences, Tehran , KhabazKhoob, Mehdi Department of Medical Surgical Nursing - School of Nursing and Midwifery - Shahid Beheshti University of Medical Sciences, Tehran , Ostadimoghaddam, Hadi Refractive Errors Research Center - School of Paramedical Sciences - Mashhad University of Medical Sciences
Pages
6
From page
69
To page
74
Abstract
Purpose: To investigate the effect of a lubricating drop on optical quality, tear film stability, and subjective symptoms in individuals wearing
silicone hydrogel contact lens.
Methods: In this one-day, prospective single-center clinical study, Pre-lens Tear Deformation Time (PL-TDT), Root-Mean-Square (RMS) of
Low Order Aberrations (LOA) and High Order Aberrations (HOA), individual twelve Zernike coefficients, and subjective symptoms were
assessed in 43 volunteers (mean age 19.58 ± 1.63, 86 eyes) at 6 h after inserting the contact lens and then at 60 min after instilling a lubricating
drop (Comfort drops, Avizor, Madrid-Spain).
Results: PL-TDT, LOA-RMS, and HOA-RMS values measured before drop instillation were not significantly different with those measured after
drop. None of the Zernike coefficients were significantly different after instilling lubricating drop. Statistically significant decrement in both
frequency and severity values in blurry vision, dryness, discomfort, burning, itching, foreign body sensation, excessive blinking, and lacrimation were seen after drop instillation (all P < 0.05).
Conclusion: Our results showed that although the lubricating drop did not improve the tear film stability and optical quality in the silicone hydrogel contact lens wearers, subjects experienced a subjective improvement.
Keywords
Lubricating drop , Tear Deformation Time , Symptom , Silicone hydrogel contact lens , Wavefront aberrations