Other language title :
اﻧﺪازهﮔﻴﺮي ﺣﺠﻢ ﻏﺪه ﺗﻴﺮوﺋﻴﺪ ﺑﺎ اﺳﺘﻔﺎده از اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﻲ: ﻣﻘﺎﻳﺴﻪاي ﺑﻴﻦ روش دوﺑﻌﺪي و روش ﺳﻪﺑﻌﺪي ﺑﺎ ﺣﺠﻢ واﻗﻌﻲ
Title of article :
Ultrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume
Author/Authors :
Vajhi, Alireza Department of Clinical Sciences - Faculty of Veterinary Medicine - University of Tehran , Rajabioun, Masoud Department of Clinical Sciences - Faculty of Veterinary Medicine - Ferdowsi University of Mashhad , Molazem, Mohammad Department of Clinical Sciences - Faculty of Veterinary Medicine - University of Tehran , Sharifi, Hamid Department of Food Hygiene and Public Health - Faculty of Veterinary Medicine - Shahid Bahonar University of Kerman
Abstract :
Objective: to compare the estimated thyroid volume, as determined by two-dimensional
(2D) and three-dimensional (3D) ultrasonography, with real volume.
Design: Descriptive Study
Animals: A total of 7 mixed breed dogs
Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation
and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in
image planes and then calculated with the inbuilt software. The real volume was
measured after Euthanasia. Correlation between actual and estimated size were computed
by using statistical software. All of the dogs must be euthanized because of clinically endstage
condition.
Results: The study demonstrates that there is a high agreement between 3D ultrasound
and real volume measured by graduated cylinder method (r=0.97, P<0.000).
Conclusion and Clinical Relevance: Evaluation of the size of thyroid gland is useful in
diagnosis of several situations and in follow-ups monitoring. Ultrasonography is supposed
to provide a reliable estimate of thyroid volume. In this study, 3D ultrasound was a useful
image method in the estimating of canine thyroid volume.
Farsi abstract :
ﺪف- ﻣﻘﺎﻳﺴﻪ ﺣﺠﻢ ﺗﺨﻤﻴﻨﻲ ﺑﺪﺳﺖ آﻣﺪه از روشﻫﺎي اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﻲ دوﺑﻌﺪي، ﺳﻪﺑﻌﺪي ﺑﺎ ﺣﺠﻢ واﻗﻌﻲ.
ﻃﺮح ﻣﻄﺎﻟﻌﻪ- ﻣﻄﺎﻟﻌﻪ ﺗﻮﺻﻴﻔﻲ
ﺣﻴﻮاﻧﺎت- 7 ﻗﻼده ﺳﮓ ﻧﮋاد ﻣﺨﻠﻮط
روش ﺑﺮرﺳﻲ- در روش دو ﺑﻌﺪي ﺣﺠﻢ ﻏﺪه ﺗﻴﺮوﺋﻴﺪ ﺑﺎ اﺳﺘﻔﺎده از ﻣﻌﺎدﻟﻪ اﻟﻴﭙﺴﻮﺋﻴﺪ و در روش ﺳﻪﺑﻌﺪي ﺑﺎ دﻧﺒﺎل ﻛﺮدن ﻣﺤﺪوده ﻏﺪه در ﺗﺼﺎوﻳﺮ ﺑﺪﺳﺖ آﻣﺪه ﺑﺎ ﻛﻤﻚ ﻧﺮم اﻓﺰار دﺳﺘﮕﺎه ﻣﺤﺎﺳﺒﻪ ﮔﺮدﻳﺪ. ﺣﺠﻢ واﻗﻌﻲ ﺑﻌﺪ از ﻛﺸﺘﻦ ﺣﻴﻮاﻧﺎت ﻣﺤﺎﺳﺒﻪ ﺷﺪ. ارﺗﺒﺎط ﺑﻴﻦ ﺣﺠﻢ واﻗﻌﻲ و ﺣﺠﻢﻫﺎي ﺗﺨﻤﻴﻦ زده ﺷﺪه ﺑﺎ اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﻲ ﺑﺎ اﺳﺘﻔﺎده از ﺑﺴﺘﻪ ﻧﺮماﻓﺰاري ﻣﺤﺎﺳﺒﻪ ﺷﺪ. ﺳﮓﻫﺎي ﻣﻮرد ﻣﻄﺎﻟﻌﻪ از ﻧﻈﺮ ﺑﺎﻟﻴﻨﻲ در ﺷﺮاﻳﻄﻲ ﺑﻮدﻧﺪ ﻣﻲ ﺑﺎﻳﺴﺖ ﻛﺸﺘﻪ ﻣﻲﺷﺪﻧﺪ.
ﻧﺘﺎﻳﺞ- اﻳﻦ ﻣﻄﺎﻟﻌﻪ ﻧﺸﺎن داد ﻛﻪ ﺑﻴﻦ ﺣﺠﻢ ﺗﺨﻤﻴﻦزده ﺷﺪه ﺑﺎ روش اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﻲ ﺳﻪﺑﻌﺪي و ﺣﺠﻢ واﻗﻌﻲ ﺗﺨﻤﻴﻦ زده ﺷﺪه ﺑﺎ روش اﺳﺘﻮاﻧﻪ ﻣﺪرج ارﺗﺒﺎط ﻣﻌﻨﻲداري وﺟﻮد دارد )r=0.97, P<0.000( .
ﻧﺘﻴﺠﻪﮔﻴﺮي و ﻛﺎرﺑﺮد ﺑﺎﻟﻴﻨﻲ- ارزﻳﺎﺑﻲ اﻧﺪازه ﻏﺪه ﺗﻴﺮوﺋﻴﺪ در ﺗﺸﺨﻴﺺ ﺑﻴﻤﺎرﻳﻬﺎ و ﻣﺎﻧﻴﺘﻮر ﻛﺮدن ﺑﻴﻤﺎر ﻛﻤﻚ ﻛﻨﻨﺪه اﺳﺖ. اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﻲ روﺷﻲ ﺑﺮاي ﺗﺨﻤﻴﻦ ﺣﺠﻢ ﻏﺪه ﺗﻴﺮوﺋﻴﺪ اﺳﺖ و در اﻳﻦ ﻣﻄﺎﻟﻌﻪ ﻣﺸﺨﺺ ﺷﺪ ﻛﻪ روش اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﻲ ﺳﻪﺑﻌﺪي ﻳﻚ روش ﻣﻔﻴﺪ ﺑﺮاي ﺗﺨﻤﻴﻦ ﺣﺠﻢ ﻏﺪه ﺗﻴﺮوﺋﻴﺪ ﻣﻲﺑﺎﺷﺪ.
Keywords :
Thyroid lobe , Canine , 3D Ultrasonography , volumetry
Journal title :
Astroparticle Physics