Other language title :
اﻧﺪازه ﮔﻴﺮي ﻓﻮاﺻﻞ زﻣﺎﻧﻲ ﺳﻴﺴﺘﻮﻟﻴﻚ ﺑﺎ اﺳﺘﻔﺎده از اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ در ﺳﮓ ﻫﺎي ﻧﮋاد ﮔﺮﻳﺖ دﻳﻦ ﺳﺎﻟﻢ
Title of article :
Echocardiographic Measurement of Systolic Time Intervals In Healthy Great Dane Dogs
Author/Authors :
Rajabioun, Masoud Department of Clinical Sciences - Faculty of Veterinary Medicine - University of Tehran , Vajhi, Alireza Department of Clinical Sciences - Faculty of Veterinary Medicine - University of Tehran , Masoudifard, Majid Department of Clinical Sciences - Faculty of Veterinary Medicine - University of Tehran , Selk Ghaffari, Masoud Department of Clinical Sciences - Faculty of Veterinary Medicine - Islamic Azad University- Karaj Branch , Sadeghian, Hakimeh Tehran Heart Centre - Faculty of Medical Sciences - Tehran University , Azizzadeh, Mohammad Department of Clinical Sciences - Faculty of Veterinary Medicine - Ferdowsi University of Mashhad
Abstract :
Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler
and m-mode echocardiography in normal, healthy Great Dane dogs.
Design- Descriptive study.
Animals- Thirty healthy Great Dane dogs.
Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional,
M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake
and unsedated. The following parameters were measured on the both Pulsed-wave
Doppler and M-mode echocardiographic images: pre - ejection period (PEP), left
ventricular ejection time (LVET), ratio of PEP to LVET (PEP/LVET) and the total
electrical-mechanical systole (QAVC). Acceleration time of aortic flow (AT) was also
measured by Doppler mode.
Results- The following values have been acquired: PEP = 0.067 ± 0.010 s; LVET = 0.188
± 0.011 s; QAVC = 0.254 ± 0.016 s and PEP/LVET = 0.354 ± 0.054 measured by Mmode
echocardiography and PEP = 0.062 ± 0.009 s; LVET = 0.193 ± 0.007 s; QAVC =
0.256 ± 0.011s; PEP/LVET = 0.323 ± 0.051 and AT = 0.080 ± 0.107 s measured by
Doppler echocardiography.
Conclusion and Clinical Relevance- On Doppler mode, there was a significant
correlation between the body weight and PEP and PEP/LVET. M-mode echocardiography showed significant correlation between the body weight and body surface area and
QAVC. Results of this study revealed the importance of determination of breed-specific
echocardiographic parameters and indices, and evaluating of measured values with range
using same method for accurate diagnosis.
Farsi abstract :
ﻫﺪف- ﺗﻌﻴﻴﻦ ﻣﺤﺪوده ﻓﻮاﺻﻞ زﻣﺎﻧﻲ ﺳﻴﺴﺘﻮﻟﻴﻚ ﺑﺎ اﺳﺘﻔﺎده از اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ داﭘﻠﺮ ﭘﺎﻟﺴﻲ و ﻣﺪ ﺣﺮﻛﺖ در ﺳﮓﻫﺎي ﻧﮋاد ﮔﺮﻳﺖ دﻳﻦ ﺳﺎﻟﻢ.
ﻃﺮح ﻣﻄﺎﻟﻌﻪ- ﻣﻄﺎﻟﻌﻪ ﺗﻮﺻﻴﻔﻲ.
ﺣﻴﻮاﻧﺎت- 30 ﻗﻼده ﺳﮓ ﺳﺎﻟﻢ ﻧﮋاد ﮔﺮﻳﺖ دﻳﻦ.
روش ﻛﺎر- در اﻳﻦ ﻣﻄﺎﻟﻌﻪ ﺗﻌﺪاد 30 ﻗﻼده ﺳﮓ ﻧﮋاد ﮔﺮﻳﺖ دﻳﻦ از ﻧﻈﺮ ﺑﺎﻟﻴﻨﻲ ﺳﺎﻟﻢ ﺗﺤﺖ اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ دوﺑﻌﺪي، ﻣﺪ ﺣﺮﻛﺖ و داﭘﻠﺮ ﭘﺎﻟﺴﻲ ﻗﺮار ﮔﺮﻓﺘﻨﺪ. ﺳﮓ ﻫﺎ ﻫﻮﺷﻴﺎر ﺑﻮدﻧﺪ و ﺑﺮاي اﻧﺠﺎم ﻛﺎر از داروﻫﺎي آرام ﺑﺨﺶ اﺳﺘﻔﺎده ﻧﺸﺪ. ﭘﺎراﻣﺘﺮﻫﺎي ذﻳﻞ ﺑﺮ روي ﺗﺼﺎوﻳﺮ ﺑﺪﺳﺖ آﻣﺪه از اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ داﭘﻠﺮ ﭘﺎﻟﺴﻲ و ﻣﺪ ﺣﺮﻛﺖ اﻧﺪازه ﮔﻴﺮي ﺷﺪﻧﺪ: زﻣﺎن ﭘـ ﻴﺶ از ﺧـﺮوج ﺧـﻮن از ﺑﻄـﻦ ﭼـﭗ )PEP(، زﻣﺎن ﺧﺮوج ﺧـﻮن از ﺑﻄـﻦ ﭼـﭗ )LVET(، ﻧﺴـﺒﺖPEP ﺑـﻪPEP/LVET) LVET ( و زﻣـﺎن ﻛﻠـ ﻲ اﻟﻜﺘﺮوﻣﻜـﺎﻧ ﻴﻜﻲ ﺳﻴﺴﺘﻮل )QAVC(. زﻣﺎن ﺷﺘﺎب ﮔﺮﻓﺘﻦ ﺟﺮﻳﺎن ﺧﻮن آﺋﻮرت )AT( ﻧﻴﺰ ﺑﺎ اﺳﺘﻔﺎده از روش داﭘﻠﺮ ﭘﺎﻟﺴﻲ اﻧﺪازه ﮔﻴﺮي ﺷﺪ. ﻧﺘﺎﻳﺞ- ﻣﻘﺎدﻳﺮ ذﻳﻞ ﺑﺎ اﺳﺘﻔﺎده از اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ ﻣﺪ ﺣﺮﻛﺖ ﺑﺪﺳﺖ آﻣﺪ:
QAVC = 0.254 ± 0.016 s ،LVET = 0.188 ± 0.011 s ،PEP = 0.067 ± 0.010 s و PEP/LVET = 0.354 ± 0.05. در اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ ﺑﺎ روش داﭘﻠﺮ ﭘﺎﻟﺴﻲ ﻣﻘﺎدﻳﺮ ذﻳﻞ ﺣﺎﺻﻞ ﺷﺪ: LVET = 0.193 ± 0.007 s ،PEP = 0.062 ± 0.009 s .AT = 0.080 ± 0.107 s و PEP/LVET = 0.323 ± 0.051 ،QAVC = 0.256 ± 0.011s ﻧﺘﻴﺠﻪ ﮔﻴﺮي و ﻛﺎرﺑﺮدﺑﺎﻟﻴﻨﻲ- در ﻣﺪ داﭘﻠﺮ، ارﺗﺒﺎط ﻣﻌﻨﻲداري ﺑﻴﻦ وزن ﺑﺪن و PEP و PEP/LVET ﺑﺪﺳﺖ آﻣﺪ. اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ ﻣﺪﺣﺮﻛﺖ ارﺗﺒﺎط ﻣﻌﻨﻲداري را ﺑﻴﻦ وزن ﺑﺪن و ﺳﻄﺢ ﺑﺪن و QAVC ﻧﺸﺎن داد. ﻧﺘﺎﻳﺞ اﻳﻦ ﻣﻄﺎﻟﻌﻪ ﺑﻴﺎﻧﮕﺮ اﻫﻤﻴﺖ ﺗﻌﻴﻦ ﭘﺎراﻣﺘﺮﻫﺎ و اﻧﺪﻳﺲﻫﺎي اﻛﻮﻛﺎردﻳﻮﮔﺮاﻓﻲ ﻣﺨﺘﺺ ﻧﮋاد و ارزﻳﺎﺑﻲ ﭘﺎراﻣﺘﺮاﻫﺎي اﻧﺪازهﮔﻴﺮي ﺷﺪه ﺑﺎ ﻣﻘﺎدﻳﺮ اﺳﺘﺎﻧﺪارد ﺑﺪﺳﺖ آﻣﺪه در روش ﻣﺸﺎﺑﻪ ﺟﻬﺖ ارزﻳﺎﺑﻲ دﻗﻴﻖ اﺳﺖ.
Keywords :
echocardiography , systolic time intervals , Great Dane , M-mode , Pulsed-wave Doppler
Journal title :
Astroparticle Physics