Other language title :
اﻧﺪازه ﮔﯿﺮي ﺷﺎﺧﺺ ﻫﺎي اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﯽ دو ﺑﻌﺪي ﮐﭙﺴﻮل ﻗﺪاﻣﯽ و ﺧﻠﻔﯽ ﻋﺪﺳﯽ ﭼﺸﻢ و ﻣﻘﺎﯾﺴﻪ ﻧﺘﺎﯾﺞ آن ﺑﺎ ﯾﮏ ﻣﻄﺎﻟﻌﻪ ﻣﯿﺪاﻧﯽ در ﺧﺮﮔﻮش
Title of article :
Ultrasonographic Measurement of the Anterior and Posterior Lens Capsules of the Eyes and its Comparison with a Field Study in Normal Rabbit
Author/Authors :
Tohidi ,Varia Department of Clinical Sciences - Faculty of Specialized Veterinary Sciences - Science and Research branch - Islamic Azad University , Veshkini, Abbas Department of Clinical Sciences - Faculty of Specialized Veterinary Sciences - Science and Research branch - Islamic Azad University , Esfahani, Mohammad Razi Department of Ophthalmology - School of Medicine - University of Tehran, , Piri, Niloufar Department of Ophthalmology - School of Medicine - University of Tehran , Vajhi, Alireza Department of Clinical Sciences - Faculty of Veterinary Medicine - University of Tehran , Nasrollahzadeh Masouleh, Mohammad Department of Clinical Sciences - Faculty of Specialized Veterinary Sciences - Science and Research branch - Islamic Azad University
Abstract :
Objective- To find normal value of thickness of the lens capsules in domesticated rabbits
by ultrasonography.
Design- experimental in vivo study and clinical trial.
Animals- Twelve matured and immature domesticated rabbit.
Procedures- The eyes of 12 non anaesthetized domesticated rabbits were sonograophed
using a linear 6-12 MHz high frequency transducer. The thickness of anterior and
posterior capsule of the lens was measured in millimeter (mm). All measurements’ were
done only by one experienced radiologist and confirmed by another radiologist. Mean and
standard errors were calculated statistically by spss statistical software.
Results were compared with ultrasonography of the eye of 75 rabbits referred to different
small animal clinic and sonographed by a radiologist.
Results- The measurement of the thickness of anterior and posterior capsule of both eyes
was 0.3979 ± 0.03255. The mean value and standard deviation of 75 clinically studied
rabbits was 0.3933 ± 0.02552.
Conclusion and Clinical Relevance- The thickness of lens capsule can be measured by
ultrasonography and this value can be used for diagnosis of production of capsular
cataract either experimentally or acquired in rabbit. There was no significant difference between thickness of anterior and posterior capsules of both eyes and has no relation to
sex, weight and age of animal.
Farsi abstract :
ﻫﺪف- ﭘﯿﺪا ﮐﺮدن اﻧﺪازه ﻃﺒﯿﻌﯽ ﺿﺨﺎﻣﺖ ﮐﭙﺴﻮل ﻋﺪﺳﯽ در ﺧﺮﮔﻮش اﻫﻠﯽ ﺑﻮﺳﯿﻠﻪ اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﯽ.
ﻃﺮح ﻣﻄﺎﻟﻌﻪ- ﻣﻄﺎﻟﻌﻪ ﺗﺠﺮﺑﯽ در ﺷﺮﯾﻂ زﻧﺪه و ﻣﻄﺎﻟﻌﻪ ﻣﯿﺪاﻧﯽ.
ﺣﯿﻮاﻧﺎت- 12 ﺳﺮ ﺧﺮﮔﻮش ﺑﺎﻟﻎ و ﻧﺎﺑﺎﻟﻎ اﻫﻠﯽ.
روش ﮐﺎر- ﭼﺸﻢ ﻫﺎي دوازده ﺳﺮ ﺧﺮﮔﻮش ﺑﺪون ﺑﯿﻬﻮﺷﯽ ﺑﺎ ﺗﺮاﻧﺲ دﯾﺴﺮ ﺧﻄﯽ ﻓﺮﮐﺎﻧﺲ ﺑﺎﻻ ﺳﻮﻧﻮﮔﺮاﻓﯽ ﺷﺪ واﻧﺪازه ﺿﺨﺎﻣﺖ ﮐﭙﺴﻮل ﻗﺪاﻣﯽ و ﺧﻠﻔﯽ ﻋﺪﺳﯽ ﺑﺮ ﺣﺴﺐ ﻣﯿﻠﯿﻤﺘﺮ اﻧﺪازه ﮔﯿﺮي ﮔﺮدﯾﺪ.
ﺗﻤﺎم اﻧﺪازه ﮔﯿﺮي ﻫﺎ ﺑﻮﺳﯿﻠﻪ ﯾﮏ ﻧﻔﺮ ﻣﺘﺨﺼﺺ رادﯾﻮﻟﻮژي اﻧﺠﺎم ﮔﺮﻓﺖ و ﻧﺘﺎﯾﺞ ﺑﺪﺳﺖ آﻣﺪه ﺗﻮﺳﻂ ﻓﺮد رادﯾﻮﻟﻮژﯾﺴﺖ دﯾﮕﺮي ﺗﺎﺋﯿﺪ ﮔﺮدﯾﺪ. ﻣﯿﺎﻧﮕﯿﻦ و اﻧﺤﺮاف ﻣﻌﯿﺎر ﺗﻮﺳﻂ ﻧﺮم اﻓﺰار SPSS ﺑﺮرﺳﯽ آﻣﺎري ﺷﺪﻧﺪ.
ﻧﺘﺎﯾﺞ- اﻧﺪازه ﺿﺨﺎﻣﺖ ﮐﭙﺴﻮل ﻗﺪاﻣﯽ و ﺧﻠﻔﯽ دو ﻫﺮ دو ﭼﺸﻢ 0/03255 ± 0/3979ﺑﻮد. اﻧﺪازه ﻣﯿﺎﻧﮕﯿﻦ و اﻧﺤﺮاف ﻣﻌﯿﺎر 75 ﺳﺮ ﺧﺮﮔﻮش در ﯾﮏ ﻣﻄﺎﻟﻌﻪ ﮐﻠﯿﻨﯿﮑﯽ 0/02552 ± 0/3933 ﺑﻮد.
ﻧﺘﯿﺠﻪ ﮔﯿﺮي و ﮐﺎرﺑﺮد ﺑﺎﻟﯿﻨﯽ- ﺿﺨﺎﻣﺖ ﮐﭙﺴﻮل ﻗﺪاﻣﯽ و ﺧﻠﻔﯽ را ﺑﻪ وﺳﯿﻠﻪ اوﻟﺘﺮاﺳﻮﻧﻮﮔﺮاﻓﯽ ﻣﯽ ﺗﻮان اﻧﺪازه ﮔﺮﻓﺖ و اﯾﻦ ﻣﻌﯿﺎر ﻣﯽ ﺗﻮاﻧﺪ ﺷﺎﺧﺼﯽ ﺑﺮاي ﺗﺸﺨﯿﺺ اﯾﺠﺎد ﮐﺎﺗﺎراﮐﺖ ﮐﭙﺴﻮﻟﯽ ﭼﻪ ﺑﻪ ﺻﻮرت اﮐﺘﺴﺎﺑﯽ و ﭼﻪ ﯾﻪ ﺻﻮرت ﺗﺠﺮﺑﯽ در ﺧﺮﮔﻮش ﺑﺎﺷﺪ. اﺧﺘﻼف ﻣﻌﻨﯽ داري ﺑﯿﻦ ﺿﺨﺎﻣﺖ ﮐﭙﺴﻮل ﺧﻠﻔﯽ و ﻗﺪاﻣﯽ ﻋﺪﺳﯽ دو ﭼﺸﻢ وﺟﻮد ﻧﺪاﺷﺖ و اﯾﻦ اﻧﺪازه ارﺗﺒﺎﻃﯽ ﺑﺎ ﺟﻨﺲ و وزن و ﺳﻦ ﺣﯿﻮان وﺟﻮد ﻧﺪاﺷﺖ.
Keywords :
Rabbit , Eye , Rabbit , Eye , Lens , Ultrasonography
Journal title :
Astroparticle Physics