Title of article
Effects of Different Doses of Fentanyl on the Sedation of Infants Under Mechanical Ventilation; A Randomized Clinical Trial
Author/Authors
Najafian ، Bita - Baqiyatallah University of Medical Sciences , Eyvazloo ، Hamed - Islamic Azad University (IAUPS), Pharmaceutical Sciences Branch , Khosravi ، Mohammad Hossein - Baqiyatallah University of Medical Sciences
Pages
4
From page
109
To page
112
Abstract
Background: Respiratory distress syndrome (RDS) is a medical emergency in infants resulting from a lack of or deficiency in surfactant, and leads to pulmonary failure. Surfactant and mechanical ventilation are among the primary treatments for helping infants with respiration. Some sedative drugs, such as benzodiazepines and opioids, are used to reduce stress and restlessness in infants under mechanical ventilation. Objective: This study aimed to evaluate the effect of 2 different dosages of Fentanyl on sedation of infants under mechanical ventilation. Methods: In this randomized clinical trial, infants with RDS were assessed, and restless infants under mechanical ventilation were included in the trial. Infants were randomly allocated into 2 groups. Infants in group A underwent treatment with 0.5 μg/kg fentanyl, and those in group B received 1 μg/kg of fentanyl. Demographic information as well as data on the duration of mechanical ventilation, length of hospital stay, and need for re-intubation were recorded on a pre-designed checklist. Results: Ultimately, 60 infants (46 male and 14 female) with a mean gestational age of 36.7±1.48 weeks in group A and 36.2±1.42 weeks in group B underwent analysis (P=0.087). Patients in group A were hospitalized for 10.36±3.59 days, and those in group B were hospitalized for 10±3.95 days (P=0.642). Mean duration of mechanical ventilation was 3.96±2.02 days in group A and 3.51±1.5 days in group B infants (P=0.459). Conclusion: The findings of the present study suggest that both doses of fentanyl (0.5 μg/kg and 1 μg/kg) reduced all parameters of respiratory distress, such as heart rate and respiratory rate, with no significant difference between the 2 doses.
Keywords
Fentanyl , Infantile Respiratory Distress Syndrome , Mechanical Ventilation
Journal title
Hospital Practices and Research
Serial Year
2017
Journal title
Hospital Practices and Research
Record number
2462787
Link To Document